Coordinate Measuring Systems
Products equipped with the measurement data output function can be connected to the measurement data network system MeasurLink ® (refer to page A-3 for details). Status monitoring boosts uptime with timely adjustments and alerts for events like busy, idle, or maintenance. Operators can optimize machine use and repurpose idle instruments for measuring other parts.
Precision measuring technology in three dimensions
Shop-floor Type CNC Coordinate Measuring Machine MiSTAR 555 MiSTAR 555 & 575
• An accuracy-guaranteed temperature range of 10 to 40° C is possible thanks to a combination of technologies, such as the symmetric guide structure, uniform material and temperature compensation. • A contamination resistance more than 2 times better than conventional Mitutoyo CMMs is achieved by adopting a newly developed environment-resistant ABSOLUTE scale*. * ABSOLUTE scale that provides an absolute XYZ-values relative to an internal reference point for each coordinate captured. This eliminates the need for an initialization operation.
• The footprint is reduced to about 80% compared to conventional moving bridge models by adopting the horizontal-arm structure and installing the CMM controller and PC under the measuring table. • Design allows open access from 3 sides.
Equipped with the PH10MQ probe head
MRT240 Rotary table diameter 240 mm
MiSTAR 555
SPECIFICATIONS
25.4 mm = 1.0 inch
Model
MiSTAR 555
MiSTAR 575
Items
X-axis Y-axis Z-axis
570 mm 500 mm 500 mm
570 mm 700 mm 500 mm
Measuring range
Maximum permissible length measurement error* 1 * 2 ISO 10360-2: 2009 (18 to 22° C)
2.2 + 3L/1000 μm
Drive speed
5 to 350 mm/s (max. combined speed 606 mm/s) in CNC MODE 1556 mm/s 2 (max. combined acceleration 2695 mm/s 2 )
Drive acceleration
Max. height Max. loading
660 mm
L
Workpiece
120 kg
180 kg
Accuracy guaranteed temperature range Mass (including the controller and installation platform)
10 to 40° C
655 kg
805 kg
*1 Specifications vary by configuration, size, and thermal environment. *2 L = Measuring length (unit: mm) Note1: W hile the appearance of the natural stone measuring table varies according to the source, the high stability for which this material is known can always be relied upon. Note2: For information about guaranteed accuracy outside of the 18 to 22º C temperature range, contact your nearest M³ Solution Center.
Refer to the MiSTAR Series Brochure ( B2321(3) ) for more details.
L-3