MAC CAT-1006 FINAL

Linear Scales

Linear Scales ST36 SERIES 579 — High Accuracy Type

• Outputs 2-phase sinusoidal wave signals at 4 μm pitch. • The maximum effective measuring length is 3000 mm when the resolution is 0.01/0.02/0.05/0.1 μm (2-phase square- wave is output). • Compact detector head enables space saving design. • Along with the output specifications of 2-phase sinusoidal wave and 2-phase square-wave, the output specification of 1 Vp-p wave is also available. • Equipped with the function to display signal errors on the LED.

SPECIFICATIONS Model

ST36

Detection method

Optical

ST36A : 2 Vp-p sinusoidal signals ST36B : 2-phase square-wave signals (RS-422A compatible), Alarm reset input ST36C : 2-phase square-wave signals (RS-422A compatible), 2-phase sinusoidal signals ST36D : 1 Vp-p differential sinusoidal signals

Output signal

H

Main scale grating pitch

8 µm 4 µm

Signal output pitch

Effective range

10 to 3000 mm

Accuracy (20º C)* 1

±0.5 µm, ±1 µm, ±2 µm/m

Maximum response speed* 2

1200 mm/s

Scale reference point Power supply voltage

10 to 80 mm: 1 center point; 100 to 300 mm: 50 mm pitch

5 VDC ± 5%

Need Support?

Operating temperature (humidity) range Storage temperature (humidity) range

0 to 40º C (20 to 80% RH, non-condensing)

–20 to 60º C (20 to 80% RH, non-condensing)

Head cable length

1 m (high-flex connecting cable)

*1

Effective range 300 mm or less 500 mm or less 1000 mm or less

Accuracy ±0.5 µm

±1 µm ±2 µm

3000 mm or less ±2 µm/m *2 Maximum response speed when sinusoidal signals are output

Refer to the NC Linear Scale Systems Brochure ( E13005 ) for more details.

H-19