Laser Scan Micrometer
Optional Accessories • Multifunctional display unit, LSM-6200 :
LSM-512S Measuring Unit SERIES 544 — 1 mm to 120 mm Measuring Unit
Order No. Remarks 542-072A English mm/in English user's manual Display type
• Ensures ±6 µm accuracy over the entire measuring range (1 to 120 mm). • The industry’s first narrow-range accuracy performance in this measuring range of ±(4.0+0.5 D) μm is available for high-accuracy measurement.
• Panel-mount type display unit, LSM-5200 :
Order No. 544-047
Remarks
English user's manual
With signal cable (5 m) 02AGN770A
• Heavy Duty Adjustable Workstage: K542965 • Standard calibration gage set (ø20.0, ø120.0): 02AGD150 • Air blower: 02AGD260 • Extension signal cable (max. 25 m)
SPECIFICATIONS Order No. (Laser only)
544-540
Order No. 02AGN780A 02AGN780B 02AGN780C 02AGN780D
Cable length
Package No. (Laser w/ LSM 6200 display)
64PKA121
5 m 10 m 15 m 20 m
Applicable laser standards
IEC, FDA
User's manual Measuring range
English version
.040" to 4.72" (1 to 120mm)
Resolution
.000005" to .005" (0.1 to 100μm) (selectable)
Repeatability* 1
±0.85μm
• Extension relay cable (max. 5 m)
Accuracy* 2 (20°C)
Whole range Small range
±6μm
±(4.0+0.5 D)μm* 3
02AGC150A 02AGC150B 02AGC150C
1 m 3 m 5 m
Positional error* 4 Measuring area* 5 Scanning rate Laser wavelength Laser scanning speed
±8μm
30×120mm (1 to 120mm)
3200 scans/s 650nm (Visible)
DIMENSIONS
Unit: mm
904m/s 0 to 40°C
Temperature
Operating environment Protection level
Humidity
RH 35 to 85% (no condensation)
LSM-512S
IP64* 6 *1: Determined by the value of ±2 ( : standard deviation) when measuring ø120mm at the interval of 0.32 sec. (average 1024 times). *2: Center of the measuring range for cylindrical workpieces outside diameter. *3: D=Difference in diameter between the master gage and workpiece (Unit: mm) *4: An error of the outside diameter due to variation in workpiece position either in the optical axis direction or in the scanning direction. *5: The area given by [optical axis direction]×[scanning direction]. *6: The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.
ø 3.1
200 100
(Measuring position)
8-M4
7
312
88
150
400
150
Signal cable
Min. 70 Cable space
700
321
272
107
G
Max. 700
48
Reception Unit
131*
190
48
Emission Unit
30
9
9
Measuring range
DIMENSIONS
Unit: mm
ø 3.1
ø3.1, depth 6
50 22
(Measuring position)
Base
M3, depth 6 (×4)
LSM-500S
LSM-503S
96
137
52
96
263
6
Relay cable
(Measuring position)
8-M3
M6, depth 12, ø5 through hole (×3) For mounting side plate (same in the back)
238
462
M6, depth 12, ø5 through hole (×3) For mounting side plate (same in the back)
192
85
256
144
202
57
M6, depth 12 (×3) For mounting base
Measuring range
M6, depth 12 (×3) For mounting base
Signal cable Min. 70
48
48
259
<Mass> Emission Unit: 3.0 kg Reception Unit: 1.2 kg Base: 1.8 kg Signal cable (5 m): 0.5 kg * Extendable up to 510 mm
11
11
355
130
Cable space
Max. 350
32
Min. 70
103
34 46
40
42
ø3.1, depth 6 (Reference hole)
42
170
55
50* 8
80
Reception Unit
ø3.1, depth 6 (Reference hole)
Measuring range
To Reception Unit (Cable length 1.4 m)
8
10
Cable space
Emission Unit
Measuring range
Dimension when disconnected (bottom view)
Working distance
1
Base
95.5
54.5
46
65.5
84.5
Relay cable
105
250
M4, depth 8, ø3.3 through hole (×3) For mounting side plate (same in the back)
M4, depth 8, ø3.3 through hole (×2) For mounting side plate (same in the back)
150
90
57
41
Measuring range
126
55
181
<Mass> Emission Unit: 1.1 kg Reception Unit: 0.6 kg Base: 0.5 kg Signal cable (5 m): 0.5 kg * Extendable up to 270 mm
ø3.1, depth 6 (Reference hole)
M4, depth 8 (×3) For mounting base
ø3.1, depth 6 (Reference hole)
M4, depth 8 (×3) For mounting base
To Reception Unit (Cable length 1.4 m)
LSM-501S
Dimension when disconnected (bottom view)
22 50
ø3.1 hole, depth 6 (Measuring position)
6
LSM-506S
8-M3
ø 3.1
22 50 100
(Measuring position)
7
12-M3
40
150
40
258
102
Signal cable
Min. 70
230
Signal cable
90
360
90
Measuring range
68 34 34* Max. 100
39
123
Cable space
Min. 70 Cable space
540
40
40
273
Max. 700
8
8
Reception Unit
42
42
82
185
110*
163
4
8
8
20
Emission Unit
Measuring range
Base
Emission Unit
115.5 71
168.5
87
87
Base
Relay cable
Reception Unit
157
73
192
348
Relay cable
M5, depth 10, ø4.2 through hole (×2) For mounting side plate (same in the back)
M5, depth 10, ø4.2 through hole (×3) For mounting side plate (same in the back)
Measuring position M4, depth 8 (×3)
40.5 38.5 30
110
M4, depth 8 (×3)
162
63
121
174.5
Measuring range
<Mass> Emission Unit: 0.7 kg Reception Unit: 0.4 kg Base: 0.3 kg Signal cable (5 m): 0.5 kg * Extendable up to 66 mm.
<Mass> Emission Unit: 1.4 kg Reception Unit: 0.8 kg Base: 0.8 kg Signal cable (5 m): 0.5 kg * Extendable up to 537 mm
ø3.1 hole, depth 6 ø3.1 hole, depth 6 Dimension when disconnected (bottom view)
To Reception Unit
ø3.1, depth 6 (Reference hole)
M5, depth 10 (×3) For mounting base
ø3.1, depth 6 (Reference hole)
M5, depth 10 (×3) For mounting base
To Reception Unit (Cable length 1.4 m)
Find a Distributor
(Cable length 0.6 m)
Dimension when disconnected (bottom view)
G-37
Powered by FlippingBook