MAC CAT-1006 FINAL

Laser Scan Micrometer

Optional Accessories • Multifunctional display unit, LSM-6200 :

LSM-512S Measuring Unit SERIES 544 — 1 mm to 120 mm Measuring Unit

Order No. Remarks 542-072A English mm/in English user's manual Display type

• Ensures ±6 µm accuracy over the entire measuring range (1 to 120 mm). • The industry’s first narrow-range accuracy performance in this measuring range of ±(4.0+0.5 D) μm is available for high-accuracy measurement.

• Panel-mount type display unit, LSM-5200 :

Order No. 544-047

Remarks

English user's manual

With signal cable (5 m) 02AGN770A

• Heavy Duty Adjustable Workstage: K542965 • Standard calibration gage set (ø20.0, ø120.0): 02AGD150 • Air blower: 02AGD260 • Extension signal cable (max. 25 m)

SPECIFICATIONS Order No. (Laser only)

544-540

Order No. 02AGN780A 02AGN780B 02AGN780C 02AGN780D

Cable length

Package No. (Laser w/ LSM 6200 display)

64PKA121

5 m 10 m 15 m 20 m

Applicable laser standards

IEC, FDA

User's manual Measuring range

English version

.040" to 4.72" (1 to 120mm)

Resolution

.000005" to .005" (0.1 to 100μm) (selectable)

Repeatability* 1

±0.85μm

• Extension relay cable (max. 5 m)

Accuracy* 2 (20°C)

Whole range Small range

±6μm

±(4.0+0.5 D)μm* 3

02AGC150A 02AGC150B 02AGC150C

1 m 3 m 5 m

Positional error* 4 Measuring area* 5 Scanning rate Laser wavelength Laser scanning speed

±8μm

30×120mm (1 to 120mm)

3200 scans/s 650nm (Visible)

DIMENSIONS

Unit: mm

904m/s 0 to 40°C

Temperature

Operating environment Protection level

Humidity

RH 35 to 85% (no condensation)

LSM-512S

IP64* 6 *1: Determined by the value of ±2 ( : standard deviation) when measuring ø120mm at the interval of 0.32 sec. (average 1024 times). *2: Center of the measuring range for cylindrical workpieces outside diameter. *3: D=Difference in diameter between the master gage and workpiece (Unit: mm) *4: An error of the outside diameter due to variation in workpiece position either in the optical axis direction or in the scanning direction. *5: The area given by [optical axis direction]×[scanning direction]. *6: The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.

ø 3.1

200 100

(Measuring position)

8-M4

7

312

88

150

400

150

Signal cable

Min. 70 Cable space

700

321

272

107

G

Max. 700

48

Reception Unit

131*

190

48

Emission Unit

30

9

9

Measuring range

DIMENSIONS

Unit: mm

ø 3.1

ø3.1, depth 6

50 22

(Measuring position)

Base

M3, depth 6 (×4)

LSM-500S

LSM-503S

96

137

52

96

263

6

Relay cable

(Measuring position)

8-M3

M6, depth 12, ø5 through hole (×3) For mounting side plate (same in the back)

238

462

M6, depth 12, ø5 through hole (×3) For mounting side plate (same in the back)

192

85

256

144

202

57

M6, depth 12 (×3) For mounting base

Measuring range

M6, depth 12 (×3) For mounting base

Signal cable Min. 70

48

48

259

<Mass> Emission Unit: 3.0 kg Reception Unit: 1.2 kg Base: 1.8 kg Signal cable (5 m): 0.5 kg * Extendable up to 510 mm

11

11

355

130

Cable space

Max. 350

32

Min. 70

103

34 46

40

42

ø3.1, depth 6 (Reference hole)

42

170

55

50* 8

80

Reception Unit

ø3.1, depth 6 (Reference hole)

Measuring range

To Reception Unit (Cable length 1.4 m)

8

10

Cable space

Emission Unit

Measuring range

Dimension when disconnected (bottom view)

Working distance

1

Base

95.5

54.5

46

65.5

84.5

Relay cable

105

250

M4, depth 8, ø3.3 through hole (×3) For mounting side plate (same in the back)

M4, depth 8, ø3.3 through hole (×2) For mounting side plate (same in the back)

150

90

57

41

Measuring range

126

55

181

<Mass> Emission Unit: 1.1 kg Reception Unit: 0.6 kg Base: 0.5 kg Signal cable (5 m): 0.5 kg * Extendable up to 270 mm

ø3.1, depth 6 (Reference hole)

M4, depth 8 (×3) For mounting base

ø3.1, depth 6 (Reference hole)

M4, depth 8 (×3) For mounting base

To Reception Unit (Cable length 1.4 m)

LSM-501S

Dimension when disconnected (bottom view)

22 50

ø3.1 hole, depth 6 (Measuring position)

6

LSM-506S

8-M3

ø 3.1

22 50 100

(Measuring position)

7

12-M3

40

150

40

258

102

Signal cable

Min. 70

230

Signal cable

90

360

90

Measuring range

68 34 34* Max. 100

39

123

Cable space

Min. 70 Cable space

540

40

40

273

Max. 700

8

8

Reception Unit

42

42

82

185

110*

163

4

8

8

20

Emission Unit

Measuring range

Base

Emission Unit

115.5 71

168.5

87

87

Base

Relay cable

Reception Unit

157

73

192

348

Relay cable

M5, depth 10, ø4.2 through hole (×2) For mounting side plate (same in the back)

M5, depth 10, ø4.2 through hole (×3) For mounting side plate (same in the back)

Measuring position M4, depth 8 (×3)

40.5 38.5 30

110

M4, depth 8 (×3)

162

63

121

174.5

Measuring range

<Mass> Emission Unit: 0.7 kg Reception Unit: 0.4 kg Base: 0.3 kg Signal cable (5 m): 0.5 kg * Extendable up to 66 mm.

<Mass> Emission Unit: 1.4 kg Reception Unit: 0.8 kg Base: 0.8 kg Signal cable (5 m): 0.5 kg * Extendable up to 537 mm

ø3.1 hole, depth 6 ø3.1 hole, depth 6 Dimension when disconnected (bottom view)

To Reception Unit

ø3.1, depth 6 (Reference hole)

M5, depth 10 (×3) For mounting base

ø3.1, depth 6 (Reference hole)

M5, depth 10 (×3) For mounting base

To Reception Unit (Cable length 1.4 m)

Find a Distributor

(Cable length 0.6 m)

Dimension when disconnected (bottom view)

G-37

Powered by