MAC CAT-1006 FINAL

Mu-checker

Display Unit (analog/digital) SERIES 519 • Switchable measurement ranges make the Mu-checker suitable for a range of applications, especially those that involve moderately fast-changing measurement values which suit the use of analog readout.

• Single touch zero-set function is standard. • Two types of analog display are available and one digital type.

Digital Mu-checker

SPECIFICATIONS

Dual Input

M-562

Model

Order No.

519-562A

Digital Mu-checker

Type

Differential type digital Mu-Checker (2 connecting heads)

Display range

±2.000 mm/±0.2000 mm/±0.08 in/±0.008 in 0.001 mm/0.0001 mm/0.00005 in/0.000005 in

Resolution

Differential mode Measurement mode

±A, ±B, ±A±B

ABS/CMP

Analog output Digital output

±1 V at full-scale reading

Digimatic code out

External dimensions

134 (W) ×183 (D) ×208 (H) mm

Mass

Approx. 2.6 kg

Power input

AC adapter 100, 120, 220, 240 V AC 50/60 Hz Various probes (refer to pages G-21 and G-22)

Probe

G

Standard type

Analog Mu-checker

SPECIFICATIONS

Dual Input

Single Input

M-554

M-553

Model

Order No.

519-554A

519-552A

Standard type (one probe required)

Differential type (one/two probes required)

Type

±5 µm/±15 µm/±50 µm/±150 µm/±500 µm/±1500 µm ±0.00015 in/±0.0005 in/±0.0015 in/±0.005 in/±0.015 in/±0.05 in 0.1 µm/0.5 µm/1 µm/5 µm/10 µm/50 µm 0.000005 in/0.00001 in/0.00005 in/0.0001 in/0.0005 in/0.001 in

±5μm/±15μm/±50μm/±150μm/±500μm/±1500μm ±.00015"/±.0005"/±.0015"/±.005"/±.015"/±.05" 0.1μm/0.5μm/1μm/5μm/10μm/50μm .000005"/.00001"/.00005"/.0001"/.0005"/.001"

Display range

Differential type

Graduation

Differential mode Display accuracy (linearity) Analog output Analog output accuracy Zero-setting adjustment range External dimensions

±A, ±B, ±A±B

±A

±1% of full-scale reading ±1.0 V at full-scale reading

Within ±0.1% of full-scale reading (excluding probe)

Optional Accessories • SPC Cable for connecting digital Mu-checker ( 936937 ) Used for connecting to the Digimatic mini-processor. (Not suitable for analog Mu-checkers) • Output cable A ( 934795 ) Used for connecting to external devices, such as data recorders, etc.

±15%/FS (error: ±0.2%/FS) 134 (W) ×183 (D) ×208 (H) mm

Mass

2.4 kg

Power input

AC adapter 100, 120, 220, 240 V AC 50/60 Hz Various probes (refer to pages G-21 and G-22)

Probe

1 m

7P

Banana chips

• Analog, limit out (7P) connector ( 529035 ) Used for output to external data recorders, sequencers, etc.

G-21