Linear Gages
SPECIFICATIONS Model
Interface unit CC-Link
Model
Interface unit EtherCAT
Order No.
21HZA186
Order No.
21HZA264
Applicable interface
EtherCAT
USB 2.0 Full Speed CC-Link Ver. 1.10 CC-Link Ver. 2.00
POWER (green), RUN (green), ERROR (red), L/A IN (green), L/A OUT (red), EJ-CONNECT (green)
Applicable interface
User Interface
Common protocols for USB and EtherCAT Readout of current value, Current value hold (software hold), Parameter setting on EJ counter, Tolerance judgment value settings, Preset valuesettings, preset/zero-set clear, peak clear, error clear
POWER (green), RUN (green), ERROR (red), EJ-CONNECT (green) Rotary switch×3 (Exchange number settings×2, communication speed settings×1) Common protocols for USB and CC-Link, Readout of current value*, Current value hold (software hold), Parameter setting on EJ counter, Tolerance judgment value settings, Preset value settings, preset/zero-set clear, peak clear, error clear * For CC-Link, Ver. 1.10 allows for transition only while Ver. 2.00 allows for both cyclic communication and transition.
Display
Functions
User Interface
Switch
Power is supplied from EJ Counter (Cannot be charged via USB)
Power supply
Operating temperature (humidity) ranges Storage temperature (humidity) ranges
0 to 50 °C (RH 20 to 80%, non-condensing)
-10 to 60 °C (RH 20 to 80%, non-condensing)
Functions
Interface unit PROFINET
Model
Order No.
21HZA187
Applicable interface
PROFINET RT (RT Class1)/USB 2.0 Full Speed
Power is supplied from EJ Counter (Cannot be charged via USB)
POWER (green), NETWORK (green/red), MODULE (green/red), LINK P0RT1 (green), LINK P0RT2 (green), EJ-CONNECT (green)
Power supply
User Interface
Operating temperature (humidity) ranges Storage temperature (humidity) ranges
Common protocols for USB and PROFINET, Readout of current value, Current value hold (software hold), Parameter setting on EJ counter, Tolerance judgment value settings, Preset value settings, preset/zero-set clear, peak clear, error clear
0 to 50 °C (RH 20 to 80%, non-condensing)
Functions
-10 to 60 °C (RH 20 to 80%, non-condensing)
Power is supplied from EJ Counter (Cannot be charged via USB)
Power supply
Operating temperature (humidity) ranges Storage temperature (humidity) ranges
0 to 50 °C (RH 20 to 80%, non-condensing)
-10 to 60 °C (RH 20 to 80%, non-condensing)
G
DIMENSIONS
EJ-102N/NE
Interface unit CC-Link
Interface unit PROFINET
2.5
56.2
2.5
56.2
With transparent cover
Without transparent cover
2.5
56.2
59.25
59.25
59.25
Interface unit EtherNet/IP
Interface unit EtherCAT
Interface unit USB
2.5
56.2
2.5
56.2
2.5
56.2
59.25
59.25
59.25
Note: Can be mounted on DIN rail. Case material: PC, POM
Where to Buy
G-14