MAC CAT-1006 FINAL

Linear Gages

SPECIFICATIONS

Resolution 0.01 µm/Accuracy 0.2 µm model

542-715A (Standard)

542-716A (Low measuring force)

Order No.

Measuring range

10 mm

Resolution

0.01 µm (0.05 µm, 0.1 µm, 0.5 µm, 1 µm can be selected from the counter)

Measuring accuracy (20 °C)* 1

0.2 µm

Repeatability (20 °C)* 1 Retrace error (20 °C)* 1

0.1 µm (2 )

0.1 µm

Contact point downwards Contact point horizontal Contact point upwards

0.65 N or less 0.55 N or less 0.45 N or less

Approx. 0.12 N Not applicable Not applicable

Measuring force

Position detection method Detectable operation speed

Optical reflection type linear encoder

In normal measurement: 700 mm/sec; for peak detection: 120 mm/sec

Mass of gage head

Approx. 370 g

Contact point

Carbide tipped, Sø3 mm (M2.5x0.45), standard contact point: 901312

Stem

ø15 mm

Bearing

Linear ball type

Output cable length

Approx. 2 m

Operating temperature (humidity) ranges Storage temperature (humidity) ranges

0 to 40 °C (Reference temperature 20 °C)/20 to 80% RH (non-condensing)

−10 to 60 °C/20 to 80% RH (non-condensing)

Counter Specifications Display range

±999.99999 mm

Functions

Zero-setting, presetting, direction changeover, tolerance judgment (3 steps/5 steps), RS-LINK

Peak hold function

Yes

Interface

RS-232C, USB (only for SENSORPAK ), Digimatic (Printer: DP-1VA LOGGER )* 3 , I/O Connector • RS-232C: counting data • Digimatic output: counting data* 3 • I/O connector: counting data (simplified BCD), tolerance judgment result, simplified analog output Zero-setting, presetting, data hold, peak measurement mode selection, peak clear

External output External control Power supply

Suppplied AC Adapter, or 12 to 24 V DC, max. 700 mA 8.4 W (max. 700 mA), ensure at least 1 A power supply per unit.

Power consumption

Mass of counter

Approx. 900 g (AC Adapter excluded)

Wrench for contact point, rubber boot, stand, washer (for counter), AC Adapter, AC cord, DC plug, user's manual, inspection certificate

Standard accessories

G

Resolution 0.005 µm/Accuracy 0.1 µm model

542-720A (Standard)

542-721A (Low measuring force)

Order No.

Measuring range

10 mm

Resolution

0.005 µm (0.01 µm, 0.05 µm, 0.1 µm can be selected from the counter)

Measuring accuracy (20 °C)* 1

0.1 µm

0.02 µm (2 σ )

Repeatability (20 °C)* 1 Retrace error (20 °C)* 1

0.05 µm

Contact point downwards Contact point horizontal Contact point upwards

0.65 N or less 0.55 N or less 0.45 N or less

Approx. 0.1 N Not applicable Not applicable

Measuring force

Position detection method Detectable operation speed

Ultra-high accuracy transmission type linear encoder

In normal measurement: 250 mm/sec

Mass of gage head

Approx. 370 g

Contact point

Carbide sphere SR5 (M2.5x0.45), standard contact point: 120058

Talk to Sales

Stem

ø15 mm

Bearing

Linear ball type

Output cable length

Approx. 2 m

Operating temperature (humidity) ranges Storage temperature (humidity) ranges

15 to 25 °C (Reference temperature 20 °C)/30 to 60% RH (non-condensing)

−10 to 60 °C/20 to 80% (non-condensing)* 2

Counter Specifications Display range

±99.999995 mm

Functions

Zero-setting, presetting, direction changeover, tolerance judgment (3 steps/5 steps), RS-LINK

Peak hold function

No

Linear Displacement Sensors LINEAR GAGE

Interface

RS-232C, USB (only for SENSORPAK ), Digimatic (Printer: DP-1VA LOGGER )* 3 , I/O Connector • RS-232C: counting data • Digimatic output: counting data* 3 • I/O connector: counting data (simplified BCD), tolerance judgment result, simplified analog output

External output External control Power supply

Zero-setting, presetting, data hold

Suppplied AC Adapter, or +12 to 24 V DC, max. 700 mA 8.4 W (max. 700 mA), ensure at least 1 A power supply per unit.

Power consumption

Mass of counter

Approx. 900 g (AC Adapter excluded)

Wrench for contact point, rubber boot, stand, washer (for counter), AC Adapter, AC cord, DC plug, user's manual, inspection certificate

Standard accessories

Bulletin No. 2326

*1 Applies when used with counter. *2 The storage temperature/humidity ranges after unpacking are the same as the operating temperature/humidity ranges. *3 When using Digimatic output, the format is d1 and is limited to 5 decimal places

Refer to the Linear Gage Brochure ( 2326 ) for more details.

G-10