MAC CAT-1006 FINAL

Linear Gages

LG200 Pencil Probe Style SERIES 542 — Environment-Resistant and Slim Type

Connector

• IP67G protection rating with superior oil-resistance compared to standard gages. • When using any EJ+interface, a free setup and viewing software is available: LG Quicksetuptool (refer to page G-15) *1 10 mm range models (Actual value from in-house tests)

• High-accuracy gage head suitable for in-line and general use. • Guaranteed Accuracy and Repeatability. • Sliding durability of 100 million+ cycles* 1 . • Can be connected to various counters such as: - EJ series - built-in display, modular, compact, with PLC interfaces, as well as USB - EH series - high-visibility display, serial and I/O communication (adapter required) - Direct to machines via TTL output from the Linear Gage

20.4

30

14.7

HR10A-10P-10P (HIROSE)

Unit: mm

Optional Accessories • Air lifter: 02ADE230 Note 1: Required air pressure: 0.2 to 0.4 MPa (With a 0.1 µm resolution type: 0.2 MPa) Note 2: Spindle extends when air is supplied.

542-187

SPECIFICATIONS Order No.

542-186

542-187

542-188

Measuring range

10 mm / .4"

Resolution

1 µm / 5 uinch

0.5 µm / .000020"

0.1 µm / .000050"

(0.8 + L/50) µm L=arbitrary measuring length (mm)

Measuring accuracy (20 °C) Small range accuracy Repeatability: 2 σ (20 °C)

(1.5 + L/50) µm L=arbitrary measuring length (mm)

0.5 µm (Arbitrary 20 µm range)

0.3 µm

Contact point downwards Contact point horizontal Contact point upwards

0.8 N or less 0.75 N or less 0.7 N or less

Measuring force

Position detection method Maximum response speed

Optical transmission-type Linear encoder

1500 mm/s

400 mm/s

G

• Rubber boot: 21HAA331 (spare) • Thrust stem set: 02ADB680

Output signal

90° phase difference, differential square wave (RS-422A equivalent)

Minimum edge intervals

500 ns (2 MHz)

250 ns (4 MHz)

(Thrust stem: 02ADB681 , Clamp nut: 02ADB682 ) This is a combination of thrust stem and a clamp nut. • Spanner wrench: 02ADB683 If required spanner wrench is required for tightening. If using multiple gages, one spanner wrench and a thrust stem set is required for each gage.

Output signal pitch

4 µm

2 µm

0.4 µm

Mass

Approx. 210 g

ø3 mm carbide tipped (fixing screw: (M2.5x0.45), standard contact point: 901312

Contact point

Stem

ø8 mm

Bearing

Linear ball type

ø11.7

Output cable length

Approx. 2.5 m (directly from casing)

Plug: HR10A-10P-10P (HIROSE), Compatible receptacle: HR10A-10R-10S (HIROSE), Compatible connector: HR10A-10J-10S (HIROSE)

Connector

Thrust stem set/Spanner Wrench

Operating temperature (humidity) ranges Storage temperature (humidity) ranges

0 to 50 °C (RH 20 to 80%, non-condensing) –10 to 60 °C (RH 20 to 80%, non-condensing)

Wrench for contact point: 538610

Standard Accessories

02ADB681 Thrust stem

DIMENSIONS

Unit: mm

ø9.5 0

ø8 0

-0.015

-0.009

02ADB682 Clamp nut

542-186/542-187/542-188

ø11.7

M9.5×0.5

• Extension cable 5 m: 21HZA197 10 m: 21HZA198 20 m: 21HZA199 Note 1: Connectable up to 3 pieces, 20 m at maximum. • Conversion Plugs / Cables Plug connection to EH-101P/102P: 21HZA195 Plug connection to EH-102Z: 21HZA196 Cable connection to EH-101P/102P: 21HZA260 Cable connection to EH-102Z: 21HZA261 Note: Connectable to EH-102Z but the function of reference point detection is disabled.

02ADB681 Thrust stem

(13.3)

Dimensions with an optional thrust stem installed

ø9.5 0

ø8 0

-0.015

-0.009

02ADB682 Clamp nut

M9.5×0.5

Custom order example • Measuring force change • Cable length change (less than 2 m) • Connector change

G-7

(13.3)

Dimensions with an optional

Powered by