MAC CAT-1006 FINAL

Dial/Digital Indicator Applications

Blade thickness measurement • Measuring faces of the contact point and anvil are blade-shaped (thickness: 1 mm). Suitable for measuring narrow grooves.

• Display: 6-digit display, sign • Power source: CR2032 battery (1 pc.), included as standard (for operational checks) • Zero-setting (INC system) • Presetting (ABS system) • Measuring direction switching • Tolerance judgment • Function Lock • Calibration schedule warning function • Data output • Display value holding (when no external device is connected) • 330° rotary display • Low battery voltage alarm display • Error alarm display

547-315A

7315A

SPECIFICATIONS Inch/Metric Order No.

Range (in)

Parallelism of Contact point, Anvil

Resolution

Measuring depth Contact point, Anvil

547-316A

0.0005 in/0.01 mm 0 - 0.4 1.18 in (30 mm)

t=1 mm (0.04 in) Blade 0.005 in/0.01 mm t=1 mm (0.04 in) Blade 0.005 in/0.01 mm

547-516A * 0.0005 in/0.01 mm 0 - 0.47* 1.18 in (30 mm)

Measuring force (N)

Mass (g)

Order No. 547-316A

Accuracy

Remarks

±0.001 in/±20 μm 1.5 or less

260 240

Blade thickness Blade thickness

Optional Accessories Refer to page F-90. • Measurement Data Management USB-ITPAK V3.0 : 06AGR543

547-516A * ±0.001 in/±20 μm 1.5 or less

* Using ID-SX Digimatic indicator.

Inch Order No. Metric Order No. 547-315A Order No. 547-315A

F

Resolution (mm)

Range (mm) 0 - 10

Measuring depth (mm)

Contact point, Anvil (mm)

Parallelism of Contact point, Anvil (μm)

0.01

30

t=1 Blade

10

Accuracy (μm)

Measuring force (N)

Mass (g)

Remarks

±20

1.5 or less

260

Blade thickness

Graduation (in)

Range (in) 0 - 0.5

Measuring depth (in)

Contact point, Anvil (in)

Parallelism of Contact point, Anvil (in)

7316A

0.001

1.18

t=0.04 Blade

0.0005

Accuracy (in)

Measuring force (N)

Mass (g)

Order No.

Remarks

7316A

±0.001

1.8 or less

220

Blade thickness

Metric Order No.

Graduation (mm)

Range (mm) 0 - 10

Measuring depth (mm)

Contact point, Anvil (mm)

Parallelism of Contact point, Anvil (μm)

7315A

0.01

30

t=1 Blade

5

Accuracy (μm)

Measuring force (N)

Mass (g)

Order No.

Remarks

7315A

±15

1.4 or less

220

Blade thickness

Note: The dial indicator needs to be reset when a contact point is replaced.

DIMENSIONS



Unit: mm

Contact point Anvil

1

30

(Throat depth)

85

30 ø 6.5

F-94

Powered by