Dial/Digital Indicator Applications
Thickness Gages SERIES 547, 7
Pipe gage measurement • Pipe wall thickness, thickness of curved boards can be measured. (Contact point, Anvil: hardened steel)
• Display: 6-digit display, sign • Power source: CR2032 battery (1 pc.), included as standard (for operational checks) • Zero-setting (INC system) • Presetting (ABS system) • Measuring direction switching • Tolerance judgment • Function Lock • Calibration schedule warning function • Data output • Display value holding (when no external device is connected) • 330° rotary display • Low battery voltage alarm display • Error alarm display
SPECIFICATIONS Inch/Metric Order No. Resolution
547-360A
7360A
Range (in)
Measuring depth
Contact point, Anvil
ø3 mm (ø0.12 in) Flat (Contact point) ø3.5 mm (ø0.14 in) Ball (Anvil) ø3 mm (ø0.12 in) Flat (Contact point) ø3.5 mm (ø0.14 in) Ball (Anvil)
547-361A 0.0005 in/0.01 mm 0 - 0.4
0.79 in (20 mm)
547-561S 0.0005 in/0.01 mm 0 - 0.47*
0.79 in (20 mm)
Measuring force (N)
Mass (g)
Order No.
Accuracy
Remarks
547-361A ±0.001 in/±20 μm 1.5 or less 547-561S ±0.001 in/±20 μm 1.5 or less
230 215
Pipe gage Pipe gage
Optional Accessories Refer to page F-90. • Measurement Data Management USB-ITPAK V3.0 : 06AGR543
* Using ID-SX Digimatic indicator.
Metric Order No.
Resolution (mm)
Range (mm) 0 - 10
Measuring depth (mm)
F
Contact point, Anvil (mm) ø3 Flat (Contact point) ø3.5 Ball (Anvil)
547-360A
0.01
20
Accuracy (μm)
Measuring force (N)
Mass (g)
Order No. 547-360A
Remarks
±20
1.5 or less
230
Pipe gage
Inch Order No.
Graduation (in)
Range (in) 0 - 0.5
Measuring depth (in)
Contact point, Anvil (in)
ø0.12 Flat (Contact point) ø0.14 Ball (Anvil)
7361A
0.001
0.8
Accuracy (in)
Measuring force (N)
Mass (g)
Order No.
Remarks
7361A
±0.001
1.8 or less
200
Pipe gage
Metric Order No.
Graduation (mm)
Range (mm) 0 - 10
Measuring depth (mm)
Contact point, Anvil (mm) ø3 Flat (Contact point) ø3.5 Ball (Anvil)
7360A
0.01
20
Accuracy (μm)
Measuring force (N)
Mass (g)
Order No.
Remarks
7360A
±15
1.4 or less
200
Pipe gage
Note: The dial indicator needs to be reset when a contact point is replaced.
DIMENSIONS
Unit: mm
Contact point
ø3 Flat
21 20 Throat depth
Sø3.5
Anvil
85
Need Repair?
F-93