Dial/Digital Indicator Applications
Lens thickness measurement • Thickness of concave-convex lenses and surfaces can be measured. (Contact point, Anvil: hardened steel) • Anvils and contact points are interchangeable to enable concave surfaces to be measured. • Provided with a ball point as standard.
Typical applications
Ball point
Flat point
Flat point
SR2
SR3
Anvil
Anvil
Anvil
547-313A
7313A
SPECIFICATIONS Inch/Metric Order No. Resolution
Concave lens
Convex lens
Plano-convex lens
Range (in)
Parallelism of Contact point, Anvil 0.005 in/0.01 mm
Measuring depth
Contact point, Anvil
Concave lens • Zero-setting (INC system) • Presetting (ABS system) • Measuring direction switching • Tolerance judgment • Function Lock • Calibration schedule warning function • Data output • Display value holding (when no external device is connected) • 330° rotary display • Low battery voltage alarm display • Error alarm display Ball point SR2 • Display: 6-digit display, sign • Power source: CR2032 battery (1 pc.), included as standard (for operational checks) SR3 Anvil Anvil Convex lens Plano-convex lens Flat point Anvil Flat point
ø6 mm (ø0.24 in) Flat (Contact point) ø4.8 mm (ø0.19 in) Flat(Anvil) ø6 mm (ø0.24 in) Flat (Contact point) ø4.8 mm (ø0.19 in) Flat (Anvil)
547-312A 0.0005 in/0.01 mm 0 - 0.4 1.18 in (30 mm)
547-512A * 0.0005 in/0.01 mm 0 - 0.47* 1.18 in (30 mm)
0.005 in/0.01 mm
Measuring force (N)
Mass (g)
Order No.
Accuracy
Remarks
547-312A ±0.001 in/±20 μm 1.5 or less 547-512A * ±0.001 in/±20 μm 1.5 or less
265 240
Lens thickness Lens thickness
* Using ID-SX Digimatic indicator.
Metric Order No.
Resolution (mm)
Range (mm) 0 - 10
Measuring depth (mm)
Contact point, Anvil (mm) ø6 Flat (Contact point) ø4.8 Flat (Anvil)
Parallelism of Contact point, Anvil (μm)
F
547-313A
0.01
30
12
Accuracy (μm)
Measuring force (N)
Mass (g)
Order No. 547-313A
Remarks
±20
1.5 or less
265
Lens thickness
Inch Order No.
Optional Accessories Refer to page F-90. • Measurement Data Management USB-ITPAK V3.0 : 06AGR543
Graduation (in)
Range (in) 0 - 0.5
Measuring depth (in)
Contact point, Anvil (in)
Parallelism of Contact point, Anvil (in)
ø0.24 Flat (Contact point) ø0.19 Flat (Anvil)
7312A
0.001
1.18
0.0005
Accuracy (in)
Measuring force (N)
Mass (g)
Order No.
Remarks
7312A
±0.001
1.8 or less
215
Lens thickness
Metric Order No.
Graduation (mm)
Range (mm) 0 - 10
Measuring depth (mm)
Contact point, Anvil (mm) ø6 Flat (Contact point) ø4.8 Flat (Anvil)
Parallelism of Contact point, Anvil (μm)
7313A
0.01
30
5
Accuracy (μm)
Measuring force (N)
Mass (g)
Order No.
Remarks
7313A
±15
1.4 or less
215
Lens thickness
Note: The dial indicator needs to be reset when a contact point is replaced.
DIMENSIONS
Unit: mm
Contact point
ø6 ø4.8
Sø 4 ball point (Standard accessory)
Reversible anvil (Traveling range 12 mm) SR3
30
(Throat depth)
85
30
F-92 ø6 ø4.8
SR2