MAC CAT-1006 FINAL

Dial Test Indicators

Set Configuration: Inch

With revolution counter

Long contact point

Carbide contact point

Full set

SPECIFICATIONS Inch

513-4XX-1XT

Standard (20° tilted face) type

Order No.

Accuracy (in)

Graduation (in)

Dial reading

Mass (g)

Measuring force (N)

Range (in)

Swivel clamp ( 900322 , for 0.157 inch DIA. stem, 0.375 inch DIA. stem, and dovetail)

Hysteresis Repeatability

Remarks

Basic set Plus set

Full set

One rev. First 2.5 rev.

Inch holding bar (L: 4 in)

— 513-442-10A 513-442-10T — 513-442-16A 513-442-16T — 513-446-10A 513-446-10T — 513-446-16A 513-446-16T — 513-443-10A 513-443-10T — 513-443-16A 513-443-16T

0.3 or less 4 4

0.3 or less 4 4 Black dial

0.0005 0.06 0-15-0 ±0.0005 ±0.0005 0.0002 ±0.0002 48

0.2 or less 4 4 4

Plus set

513-4XX-1XA

0.2 or less 4 4 4 Black dial

0.3 or less 4 4

0.0001 0.016 0-4-0 ±0.0002 ±0.0002 0.0001 ±0.00004

0.3 or less 4 4 Black dial

Stem, 0.157 inch DIA.

0.118 inch DIA. contact point (carbide)

0.039 inch DIA. contact point (carbide)

Metric

Standard (20° tilted face) type

Order No.

Accuracy (μm)

Graduation (mm)

Dial reading

Mass (g)

Measuring force (N)

Range (mm)

Hysteresis Repeatability 10 scale divisions 513-444-10E 513-444-10A 513-444-10T 0.01 1.6 0-40-0 16 10 5 5 3 Basic set Plus set Full set Measuring range One rev. 513-445-10E 513-445-10A 513-445-10T 0.0020.40-100-0 6 52 4 1

Remarks

4 4 4 4

48 0.3 or less

Basic set

513-4XX-10E

Inch

Vertical type

Order No.

Accuracy (in)

Graduation (in)

Dial reading

Mass (g)

Measuring force (N) 0.3 or less 0.3 or less

Range (in)

Hysteresis Repeatability

Remarks

Basic set Plus set One rev. First 2.5 rev. 513-452-10E — 513-452-10T 0.0005 0.03 0-15-0 ±0.0005 — 0.0002 ±0.0002 46 Full set 513-453-10E — 513-453-10T 0.0001 0.008 0-4-0 ±0.0001 — 0.0001 ±0.00004

Knurled clamp ring

Stem, 0.375 inch DIA.

4 4

Metric

Vertical type

513-4XX-1X is indicated on the dial face.

Order No.

Accuracy (μm)

Graduation (mm)

Measuring force (N)

Range (mm)

Dial reading

Mass (g)

Hysteresis Repeatability

Remarks

One rev.

10 scale divisions

Measuring range

Basic set Plus set

Full set

F

513-456-10E — — 513-454-10E 513-454-10A 513-454-10T

0.5 0-25-0 6 — 0.8 0-40-0 9 —

4 4 4

5 4 3

0.01

46 0.3 or less

0.079 inch DIA. contact point (carbide)

513-455-10E 513-455-10A 513-455-10T 0.002 0.2 0-100-0 4 — 2 3 1

Inch

Horizontal Type

Indicator

Order No.

Accuracy (in)

Graduation (in)

Dial reading

Mass (g)

Measuring force (N)

Range (in)

Hysteresis Repeatability

Remarks

Basic set Plus set One rev. First 2.5 rev. — 513-482-10A 513-482-10T 0.0005 0.03 0-15-0 ±0.0005 — 0.0002 ±0.0002 53 0.3 or less Full set

Set Configuration: Metric Full set

4

Metric

Horizontal Type

513-4XX-10T

Order No.

Accuracy (μm)

Graduation (mm)

Dial reading

Mass (g)

Measuring force (N)

Range (mm)

Hysteresis Repeatability

Remarks

One rev.

10 scale divisions

Measuring range

Basic set Plus set

Full set

513-486-10E — — 513-484-10E 513-484-10A 513-484-10T 513-485-10E — —

0.5 0-25-0 6 — 0.8 0-40-0 9 —

4 4 4

Swivel clamp ( 900321 , for ø4 mm stem, ø8 mm stem, and dovetail)

5 4 3

0.01

53 0.3 or less

Metric holding bar (L: 100 mm)

0.002 0.2 0-100-0 4 — 2 3 1

Plus set

513-4XX-10A

DIMENSIONS

Standard (20° Tilted Face) Type



Unit: mm

ø3 mm contact point (carbide)

ø1 mm contact point (carbide)

Stem, ø4 mm

L1

55.7

L2

Vertical Type

Order No. L1 L2 513-445-10E 18.7 15.2 513-444-10E 20.9 17.4

Basic set

513-4XX-10E

ø40

17.6

Knurled clamp ring Stem, ø8 mm

59.7

24.1

17.6

Horizontal Type

24.1

513-4XX-10 is indicated on the dial face.

20.4

7

17.6

Order No. L1 L2 513-484-10E 20.9 17.4 513-485-10E 18.7 15.2 513-486-10E 22.2 18.7

Order No. L1 L2 513-454-10E 20.9 17.4 513-455-10E 18.7 15.2 513-456-10E 22.2 18.7

72.1

24.1

ø2 mm contact point (carbide)

ø40

Indicator

L2

22.3

45.9

L1

Note: A slight difference may occur depending on the center of the contact point, graduation plate, and stem fixing position, etc.

F-79