MAC CAT-1006 FINAL

Dial Indicators

• Back plunger type dial indicators are suitable for mounting onto leveling machine tool tables or inspection jigs, and for use in situations where standard dial indicators are difficult to read. • Models 1960A and 1961A , which use proprietary Mitutoyo shock-proofing mechanism, have excellent durability and shock resistance. Back Plunger Type Dial Indicators SERIES 1

Holding bar

1160A

SPECIFICATIONS Inch

ANSI/AGD type

ISO/JIS type

Stem ø3/8", #4-48 UNF

Accuracy (in)

Range (range / rev) (in)

Repeatbility (in)

Dial reading

Measuring force (N)

Holding bar (optional) Order No. øD (mm)

Order No. Graduation (in)

First 1 Rev/2.5 Rev/10 Rev

Retrace

L (mm)

1961A 1166A 1167A 1168A

0.001 0.04 (0.05) 0.001 0.2 (0.05) 0.001 0.2 (0.05) 0.001 0.2 (0.05)

±0.001/—/—

0.0002 ±0.0002 20-0-20 1.4 or less 0.00033 ±0.0002 ±0-50 1.4 or less 0.00033 ±0.0002 0-25-0 1.4 or less 0.00033 ±0.0002 50-0 1.4 or less

21AAA166

ø6 ø6

42 81 81 42 42

±0.001/±0.001/±0.001 ±0.001/±0.001/±0.001 ±0.001/±0.001/±0.001

136567 124625

ø6.35 ø6.35

21AAA167 21AAA168

Metric

Stem ø8mm, M2.5x0.45 Thread

ø8 ø8

Accuracy (µm)

136568 81 Note: øD and L: detail shown in drawing below.

Range (range / rev) (mm)

Repeat- ability

Dial reading

Measuring force (N)

Graduation (mm)

Order No.

Hysteresis

Measuring range

1/10 Rev 1/2 Rev 1 Rev

F

1960A 1160A 1162A

0.01 0.01 0.01

1 (1.27)

8 8 8

— — 14

4 4 4

3 50-0-50 1.4 or less 3 ±0-100 1.4 or less

Optional Accessories • Limit hand (2 pcs.): 21AAB363

5 (1) 5 (1)

12 12

14 14

16 16

3

100-0 1.4 or less

Note 1: The bezel clamp cannot be used.

DIMENSIONS  ISO/JIS Type

Unit: mm

Unit: in

ANSI/AGD Type

øA

øA

Holding bar (optional)

Holding bar (optional)

L

L

ø8 0

ø0.375 0

-0.009

-0.0012

ø4

ø0.16

E

Ball contact (ø0.12) 21BZB056 (thread: No. 4-48 UNF)

øC

E

øC

M2.5×0.45

Order No.

Order No.

Mass (g) (Bar excluded)

Mass (g) (Bar excluded)

A B C E F G H

A B C E F G H

1160A 40 22.7 35 21.8 25 13.8 43.3 80 1162A 40 22.7 35 21.8 25 13.8 43.3 80 1960A 40 22.7 35 21.8 28.7 12.8 46 80

1166A 1.57 0.89 1.38 7/8 0.98 0.51 1.67 80 1167A 1.57 0.89 1.38 7/8 0.98 0.51 1.67 80 1168A 1.57 0.89 1.38 7/8 0.98 0.51 1.67 80 1961A 1.57 0.89 1.38 7/8 0.98 0.43 1.59 80

Note 1: Contact point (standard accessory) for all products in this page has a role as a top dead point stopper. When replacing it with an optional contact point with a connector not exceeding ø7 mm in outside diameter, insert a washer (with ø7 mm outside diameter, ø3 mm inside diameter, and approximately 0.5 mm thickness) above the contact point. Note 2: Refer to pages F-63 to F-68 for details of contact points.