MAC CAT-1006 FINAL

EC Counter

EC Counter SERIES 542 — Low-cost, Modular Type Display Unit

Functions • Preset • Tolerance judgment (3 steps)

• The counter can be connected to a gage that has a data output function, such as a Digimatic indicator or linear gage. • 3 sets of limiting values can be displayed and output. • Compact size (DIN 96×48 mm)

542-007

SPECIFICATIONS Order No.

542-007A

0.0005 in (±99.9995 in) 0.001 in (±999.999 in) 0.00005 in (±9.99995 in) 0.0001 in (±99.999 in) 0.01 mm (±9999.99) 0.001 mm (±9999.999) [automatic setting by gage]

Resolution ( ) indicates maximum display range

Tolerance judgment display

LED display (3 steps: Amber, Green, Red)

Tolerance judgment output

–NG, OK, +NG (open-collector)

External output (switching type)

Data output

Digimatic output

Control input

External PRESET, external HOLD

Operating temperature Storage temperature External dimensions

0 to 40 °C (RH 20 to 80%, no condensation) –10 to 50 °C (RH 20 to 80%, no condensation)

F

96 (W) ×48 (H) ×84.6 (D) mm AC adapter: 12BAR954 AC cable: 12BAK730 AC adapter, AC cable, rubber feet

Power Source

Standard Accessories

Mass

500 g

DIMENSIONS



Unit: mm

91.4

44.4

48

96

92 +0.8 0

F-24

パネルカット寸法