Indicators
ABSOLUTE Digimatic Indicator ID-CJX SERIES 543 — Signal Output Function Type
Functions • Signal output (–NG/OK/+NG, N-ch open drain, logical invert is available) • Remote control (peak start preset/zero-set) • Peak detection (MAX/MIN) • Runout range measurement (MAX - MIN) • Zero-setting (INC system) • Presetting (ABS system) • Measuring direction switching • Tolerance judgment (3 pairs of ABS, INC memory function) • Resolution switching • Simple calculation: f(x) =Ax • Key lock • Calibration mode (Signal output in Digimatic code format) • Error alarm display Optional Accessories • Lifting* * Dust-water protection is not guaranteed. • Digimatic power supply unit: 21EZA345A Used in the calibration mode when executing automatic inspection using i-Checker IC2000 . In such a case, purchase connection cable 21EAA194 (1 m), or 21EAA190 (2 m). Note: It can’t be used as a power source when using in the normal mode. • C ontact points for Mitutoyo’s Digimatic indicators (optional) Lifting lever 21EZA198 Lifting knob 21EZA105
• Powered by external devices / machines. See optional accessories for Mitutoyo power supply options. • Enables the Go/No-go judgment result to be output to external equipment. Output is enabled by directly connecting to an external device such as a sequencer, contributing to automation of measurement processes. It also supports logical invert of signal output. • The Go/No-go judgment result is also indicated by the green/red LED and the signs on display. • A peak detection function is equipped for measuring and judging peak values such as MAX, MIN, or Runout. • The ABS (ABSOLUTE) scale restores the last origin position* automatically when the indicator is turned on, and realizes high reliability by eliminating over-speed errors. * Refer to “Precautions for use” on page F-2.
Refer to pages F-63 to F-68 for details. • Interchangeable back covers (optional) Refer to pages F-69 to F-70 for details. Output signals and display Wire – NG OK + NG Orange (– NG) Low High High
F
543-350-10
ABS data composition error
SPECIFICATIONS Inch/Metric
High High High
ASME/ANSI /AGD type
Green (OK)
High Low High
Measuring force (N)
Mass (g)
Brown (+ NG) High High Low
Order No.
Range Resolution Accuracy (in)
Hysteresis
Repeatability
LED
Red Green Red Red flashing
0.00005/ 0.0001/ 0.0005 in, 0.001/ 0.01 mm (selectable)
“x.xxE” indication
Display
543-352-10
295
Note: Logical invert is available.
0.5 in/ 12.7 mm
±0.00010
0.00010
0.00010
2.5 or less
543-352B-10 (flat back)
I/O Specifications Wire Signal
285
I /O
Description
Connected to minus (-) terminal
Black
– V (GND)
—
Inch/Metric
ISO/JIS Type
Measuring force (N)
Mass (g)
Accuracy (mm)
Red
+ V
— Power supply (5 to 24 VDC)
Order No.
Hysteresis H MPE Repeatability R MPE
Range Resolution
Orange Green
– NG O Tolerance judgment result output: Only the
OK
O
0.00005/ 0.0001/ 0.0005 in, 0.001/ 0.01 mm (selectable) ISO/JIS Type Resolution (mm) 0.001 / 0.01 (selectable)
terminal corresponding to a judgment result is set to the low level. External input terminal: If the relevant terminal is set to the low level, its signal becomes true.
543-351-10
295
Brown
+ NG O
0.5 in/ 12.7 mm
0.003
0.003
0.002
2.5 or less
543-351B-10 (flat back)
PRESET_RECALL ZERO
285
Yellow
I
Blue PEAK_START I Shield
Metric
FG — Connected to GND (Earth)
Measuring force (N)
Mass (g)
Range (mm)
Accuracy (mm)
Order No.
Hysteresis H MPE Repeatability R MPE
Note: Measurement data cannot be output.
543-350-10 543-350B-10 (flat back)
295
Output
12.7
0.003
0.003
0.002
2.5 or less
285
OUT
Note 1: Display readout does not rotate. Note 2: MAX/MIN holding: sample rate is 100 readings/s; max. rate of change of reading is 100 μm/s or less. Note 3: Standard contact point: 901312 (ISO/JIS type), 21BZB005 (ANSI/AGD type)
Load
GND
External power
Load voltage: 5 to 24 VDC Max. load current: 100 mA or less
Input
5 to 24 VDC
1.2 k Ω
IN
GND
Switch, etc.
Input current: Max. 20 mA
F-20
Output circuits (Orange, Green, Brown)
OUT