Indicators
ABSOLUTE Digimatic Indicator ID-CRX SERIES 543 — Calculation Type
• This expandable indicator incorporates an internal calculation function that operates from plunger displacement. Using dedicated fixtures and setting the calculation coefficients, you can read your measurements directly without the need for conversions. • By using the parameter setup kit (optional) and the dedicated software, the functions and the parameters can be configured using a computer. • Five buttons, status icons, and clear button indications allow easy operation and various functions.
Typical application
Functions • Calculation f (x’) =Ax’+B+Cx’ –1 (x’=x+offset) • Peak detection (MAX/MIN) • Runout (MAX - MIN) Hold Note: Peak detection
1) Sampling rate: 10 readings/s 2) Capturing speed: 10 µm/s (max.) 1) Sampling rate: 50 readings/s 2) Capturing speed: 50 µm/s (max.)
Settings can be changed to:
543-342B-10
F
• Zero-setting (INC system) • Preset (ABS system) • Tolerance judgment (3 pairs of ABS, INC memory function) • Analog bar resolution selectable • Key lock • Display hold (when no external device is connected) • Data output • External PC setting input • Display rotation (330 ° ) • Low battery voltage alarm display • Error alarm display • Resolution switching* Resolution (mm)
SPECIFICATIONS Inch/Metric
ASME/ANSI /AGD type
Resolution (selectable)
Accuracy (in)
Battery life (normal use)
Mass (g)
Order No.
Range
Hysteresis Repeatability Measuring force (N)
0.5 in/ 12.7 mm 1 in/ 25.4 mm 2 in/ 50.8 mm
543-342B-10
170
1.5 or less
±0.00010
Approx. 1 year
543-592B-10
1.8 or less
190
12 steps
0.00010 0.00010
543-597B-10
±0.00025
2.3 or less
260
Resolution (in) 0.00001 0.0002 0.005 0.00002 0.0005 0.01 0.00005 0.001 0.02 0.0001 0.002 0.05
0.0002 0.005 0.1 0.0005 0.01 0.2 0.001 0.02 0.5 0.002 0.05 1
Inch/Metric
ISO/JIS Type
Repeatability R MPE
Battery life (normal use)
Mass (g)
Resolution (selectable)
Accuracy (mm)
Hysteresis H MPE
Order No.
Measuring force (N)
Range
0.5 in/ 12.7 mm 1 in/ 25.4 mm 2 in/ 50.8 mm
543-341B-10
170
1.5 or less
* Since the calculation resolution is one micrometer (0.001 mm), using sub-micrometer resolution settings may result in the 4th-place digit being unreliable, particularly when B is set to a very low value and C=0. It does not change at all with certain combinations of calculation coefficient (for example, A=1, B=C=0). The 3rd-place digit representing micrometers (if displayed) is always reliable.
0.003
Approx. 1 year
543-591B-10
1.8 or less
190
12 steps
0.003
0.002
543-596B-10
0.006
2.3 or less
260
Metric
ISO/JIS Type
Repeatability R MPE
Battery life (normal use)
Mass (g)
Range (mm)
Resolution (selectable)
Accuracy (mm)
Hysteresis H MPE
Order No.
Measuring force (N)
Optional Accessories Refer to page F-13.
543-340B-10 543-590B-10 543-595B-10
12.7 25.4 50.8
1.5 or less 1.8 or less 2.3 or less
170 190 260
0.003
Approx. 1 year
12 steps
0.003
0.002
0.006
• Lifting Lifting lever 21EZA198 (0.5 inch /12.7 mm type) Lifting knob 21EZA105 (0.5 inch /12.7 mm type)
• Power source: CR2032 battery (1 pc.), included as standard
21EZA197 (1 inch /25.4 mm type) 21EZA200 (2 inch /50.8 mm type)
• Parameter setup kit (optional) Refer to page F-13 for details.
F-17