MAC CAT-1006 FINAL

Depth Gage

ABSOLUTE Digimatic Depth Gage SERIES 571

• Made of hardened stainless steel with micro-lapped base and measuring faces. • Enables stable depth measurement with a resolution of .0005 in/0.01mm.

• Optional longer extension bases are available (refer to page D-78). • Data output function allows integration into statistical process control and measurement systems (refer to section A).

Optional Accessories Order No. Type

Description

USB Input Tool Series USB Keyboard Signal Conversion Type IT-020U

264-020

959149

C Connection cable (1 m)

959150

C Connection cable (2 m)

06AFM380C

C USB Input Tool Direct (2 m)

571-211-30

Base

02AZD730G IP67 U-WAVE-T

D

SPECIFICATIONS Inch/Metric Order No.

02AZD880G Buzzer U-WAVE-T

02AZE200

U-WAVE-T mounting bracket

Range (in)

Resolution Battery life Base (W×T) (in)

Accuracy* (in)

571-211-30 571-212-30 571-213-30 571-214-10 * 2 571-215-10 * 2 571-216-10 * 2 571-217-10 * 2

0 - 6 0 - 8

3.93×0.23

±0.001 in/±0.02 mm

Connection cable for U-WAVE-T For foot switch Connection cable for U-WAVE-T (160 mm) Connection cable for U-WAVE-T For foot switch

Approx. 5 years

02AZE140A

A

0 - 12 0 - 18 0 - 24 0 - 30 0 - 40

3.93×0.25

±0.0015 in/±0.03 mm

0.0005 in/ 0.01mm

±0.002 in/±0.05 mm

02AZD790C

C

Approx. 3 years 9.8×0.39

±0.0025 in/±0.06 mm ±0.0025 in/±0.07 mm

02AZE140C

C

Metric

Range (mm) 0 - 150 0 - 200 0 - 300 0 - 450 0 - 600 0 - 750 0 - 1000

Resolution (mm)

Base (W×T) (mm)

Order No. 571-201-30 571-202-30 571-203-30 571-204-10 * 2 571-205-10 * 2 571-206-10 * 2 571-207-10 * 2

Accuracy* (mm)

Battery life

264-620

IP67 U-WAVE-TC

100×6

±0.02

Approx. 5 years

264-621

Buzzer U-WAVE-TC *

100×6.3

±0.03

0.01

±0.05

264-624

IP67 U-WAVE-TCB

Approx. 3 years

250×10

±0.06 ±0.07

264-625

Buzzer U-WAVE-TCB *

• Power source: SR44 battery (1 pc.), 938882 included as standard (for operational checks) • Position detection method: Electrostatic capacity absolute sensor * E MPE (ISO 13385-2:2020). Largest value across the measuring range *1 Maximum permissible error, E MPE , is the term defined by ISO 13385-2:2011 *2 Cannot be used with U-WAVE-TC

Connecting unit for U-WAVE-TC / TCB (for models with a range up to 300 mm/12 in)

02AZF300

DIMENSIONS

959143

— Data hold unit

* Cannot be used with 571-20X-10 and 571-21X-10 .



Unit: mm

L

W

25

13

4-ø9

571-201-30, 571-202-30, 571-203-30, 571-211-30, 571-212-30, 571-213-30

9.5

2 × ø5

10 7

Range (mm)

L

W Base thickness

0 - 150 0 - 200 W L 0 - 300 0 - 450 0 - 600 0 - 750

239 289 403 635 785

59.2

6

71

6.3

571-204-10, 571-205-10, 571-206-10, 571-207-10, 571-214-10, 571-215-10, 571-216-10, 571-217-10

12.5

94

10

Thickness of main beam

935 0 - 1000 1200

Got Questions?

9.5

2 × ø5

7 10

D-70

Powered by