MAC CAT-1006 FINAL

Data Collection Software for Excel USB-ITPAK V3.0 Measurement Data Collection Software USB-ITPAK V3.0 ( IT-016U / IT-020U / USB-ITN / U-WAVE / DP-1VA LOGGER can be used to send the data to a Microsoft ® Excel ® worksheet.) •  USB-ITPAK V3.0 creates a procedure to input data from gages equipped with Digimatic output to Excel spreadsheets via 264-020 , USB-ITN or U-WAVE . This optional software facilitates the daily inspection work for mass-produced products.

Optional Accessories Model USB-ITPAK V3.0 Order No. 06AGR543 (USB dongle only) Compatible OS (Windows) Windows 10 and 11 (64 bit only)

A

Full Version

V3.0 (Free version)

Function

Compatible Excel version Excel 2010, 2013, 2016, Microsoft 365 Upgrading from V1.0 / V2.0 is not supported.

Main features of USB-ITPAK V3.0 • Setting of Microsoft Excel input: Designation of where to input (workbook, worksheet, cell range), cursor move (right, down), and others. • Selection of measuring method (3 modes available) 1) Sequential measurement 2) Simultaneous measurement 3) Individual measurement. • Control item and instruction at data input ✓ 1 Setting of measuring instrument: Sets the calibration year and month, preset values, zero-setting, etc. for a measuring instrument ✓ 1 ✓ 1 Measurement history: Records operators and measuring tools used in measurement data Symbol: ✓ 1 : Can be used only when connected with USB-ITPAK V3.0 , ID-CNX / ID-FNX and 06AGQ001A, 06AGQ001F / 264-020 . ✓ : Can be used — Cannot be used Note 1: V3.0 can be downloaded from our website. Note 2:  V3.0 , full version can be used by purchasing V3.0 ( 06AGR543 ) and connecting a USB dongle to your PC. Simple measurement function: Automatically sorts measurement data and inserts the data into different columns in Excel — ✓ Sequential measurement: Inserts measurement data into the inspection certificate (Excel) — ✓ — ✓ Individual measurement: Collects measurement data of separately conducted inspections into a single PC ✓ ✓ Simultaneous measurement: Simultaneously collects measurement data from multiple measuring instruments mounted on a jig ✓ 1

USB dongle

USB-ITPAK V3.0

Download software

A USB dongle must be connected to the PC running the software.

Foot switch + USB-FSW

Data switch when using U-WAVE

Data switch other than U-WAVE

Control item

Mouse operation Function key

Operating environment

Data output request

✓ * 1 ✓ * 1 ✓ * 1

✓ * 1 ✓ * 1 ✓ * 1

✓ * 2

✓ ✓ ✓

USB-ITPAK V3.0 : Windows 10 and 11 (64 bit only)

Compatible OS* 1

Data cancel

✓ Press and hold * 2

Data skip

USB-ITPAK V3.0 : 2010, 2013, 2016 Microsoft 365

Supported Excel versions* 2

✓ Pre-registered

Character input (example: OK or NG etc.)

character strings

*1 Not available during individual measurement. *2 Not available during simultaneous measurement in the event driven mode.

USB-ITPAK V3.0 : Free space of more than 15 MB

Hard disk

• Number of connectable gages

CD-ROM drive For program installation* 4 USB port* 3 2 ports or more Monitor resolution USB-ITPAK V3.0 :

Available devices

Maximum number of connection (total of (1), (2), and (3))

Others

1) Input Tool / Input Tool Direct 2) USB-FSW 3) U-WAVE-R Up to 100 gages connectable to each U-WAVE-R . ( U-WAVE-T ID: 00 to 99 )

• Maximum registration (total of (1), (2), and (3)) 400 units • Control/identification of connecting gage VCP (Virtual COM port) Switch from HID to VCP for (1) and (2). The VCP driver software is supplied with USB-ITPAK .

For Windows 2000/XP Up to 100 units* 3 For Windows Vista/7/8/8.1/10 Up to 20 units* 3 For U-WAVE-R , plus 100 per unit ( in terms of available gages. )

1024×768, 256 colors or more

*1 32-bit, 64-bit OS supported *2 Operation with Excel for MAC OS is not guaranteed. *3 A commercially available hub can be used. (USB certified product is recommended) *4  V3.0 does not require a CD drive but does require an Internet connection for download.

• Data loading time : when using USB Input Tool and Input Tool Direct cables, 0.2 s to 0.3 s per gage unit U-WAVE event driven mode: 0.5 s data refresh interval • Timer input function (only in simultaneous measurement) Input interval (time): 0.1 s* 4 to 24 hours at maximum • Measurement date / time display function (available in sequential and simultaneous measurements) The display format is subject to the setting of the Excel sheet. *3 The actual number can be less depending on the system configuration. *4 If a shorter time is set, a priority is given to the longer time compared with the actual communication time.

Optional Accessories for USB-ITPAK

USB Foot Switch Adapter USB-FSW

This USB adapter for connecting a PC is required when using the Foot Switch ( 937179T ) in USB-ITN . A dedicated VCP driver for this adapter is included in USB-ITPAK .

Language support • Operation language (15 languages)

• With USB-ITPAK , application of the foot switch can be set. • Data control: “Data request”,“Data cancel”, “Data skip” • Character string input (e.g. GO/NG, etc.) Note: USB-FSW is used for installation of the VCP driver. Main specification

Japanese, English, German, French, Spanish, Italian, Czech, Swedish, Turkish, Polish, Hungarian, Russian, Korean, Chinese (traditional / simplified)

Foot switch ( 937179T )

• Operation manual (PDF file) Japanese, English, German Order No. Model USB-FSW Order No. 06ADV384

Foot Switch Adapter USB-FSW

USB-FSW

Overall length: 160 mm