Data Collection Software for Excel USB-ITPAK V3.0 Measurement Data Collection Software USB-ITPAK V3.0 ( IT-016U / IT-020U / USB-ITN / U-WAVE / DP-1VA LOGGER can be used to send the data to a Microsoft ® Excel ® worksheet.) • USB-ITPAK V3.0 creates a procedure to input data from gages equipped with Digimatic output to Excel spreadsheets via 264-020 , USB-ITN or U-WAVE . This optional software facilitates the daily inspection work for mass-produced products.
Optional Accessories Model USB-ITPAK V3.0 Order No. 06AGR543 (USB dongle only) Compatible OS (Windows) Windows 10 and 11 (64 bit only)
A
Full Version
V3.0 (Free version)
Function
Compatible Excel version Excel 2010, 2013, 2016, Microsoft 365 Upgrading from V1.0 / V2.0 is not supported.
Main features of USB-ITPAK V3.0 • Setting of Microsoft Excel input: Designation of where to input (workbook, worksheet, cell range), cursor move (right, down), and others. • Selection of measuring method (3 modes available) 1) Sequential measurement 2) Simultaneous measurement 3) Individual measurement. • Control item and instruction at data input ✓ 1 Setting of measuring instrument: Sets the calibration year and month, preset values, zero-setting, etc. for a measuring instrument ✓ 1 ✓ 1 Measurement history: Records operators and measuring tools used in measurement data Symbol: ✓ 1 : Can be used only when connected with USB-ITPAK V3.0 , ID-CNX / ID-FNX and 06AGQ001A, 06AGQ001F / 264-020 . ✓ : Can be used — Cannot be used Note 1: V3.0 can be downloaded from our website. Note 2: V3.0 , full version can be used by purchasing V3.0 ( 06AGR543 ) and connecting a USB dongle to your PC. Simple measurement function: Automatically sorts measurement data and inserts the data into different columns in Excel — ✓ Sequential measurement: Inserts measurement data into the inspection certificate (Excel) — ✓ — ✓ Individual measurement: Collects measurement data of separately conducted inspections into a single PC ✓ ✓ Simultaneous measurement: Simultaneously collects measurement data from multiple measuring instruments mounted on a jig ✓ 1
USB dongle
USB-ITPAK V3.0
Download software
A USB dongle must be connected to the PC running the software.
Foot switch + USB-FSW
Data switch when using U-WAVE
Data switch other than U-WAVE
Control item
Mouse operation Function key
Operating environment
Data output request
✓ * 1 ✓ * 1 ✓ * 1
✓ * 1 ✓ * 1 ✓ * 1
✓ * 2
✓ ✓ ✓
✓
USB-ITPAK V3.0 : Windows 10 and 11 (64 bit only)
Compatible OS* 1
Data cancel
✓ Press and hold * 2
Data skip
USB-ITPAK V3.0 : 2010, 2013, 2016 Microsoft 365
Supported Excel versions* 2
✓ Pre-registered
Character input (example: OK or NG etc.)
character strings
*1 Not available during individual measurement. *2 Not available during simultaneous measurement in the event driven mode.
USB-ITPAK V3.0 : Free space of more than 15 MB
Hard disk
• Number of connectable gages
CD-ROM drive For program installation* 4 USB port* 3 2 ports or more Monitor resolution USB-ITPAK V3.0 :
Available devices
Maximum number of connection (total of (1), (2), and (3))
Others
1) Input Tool / Input Tool Direct 2) USB-FSW 3) U-WAVE-R Up to 100 gages connectable to each U-WAVE-R . ( U-WAVE-T ID: 00 to 99 )
• Maximum registration (total of (1), (2), and (3)) 400 units • Control/identification of connecting gage VCP (Virtual COM port) Switch from HID to VCP for (1) and (2). The VCP driver software is supplied with USB-ITPAK .
For Windows 2000/XP Up to 100 units* 3 For Windows Vista/7/8/8.1/10 Up to 20 units* 3 For U-WAVE-R , plus 100 per unit ( in terms of available gages. )
1024×768, 256 colors or more
*1 32-bit, 64-bit OS supported *2 Operation with Excel for MAC OS is not guaranteed. *3 A commercially available hub can be used. (USB certified product is recommended) *4 V3.0 does not require a CD drive but does require an Internet connection for download.
• Data loading time : when using USB Input Tool and Input Tool Direct cables, 0.2 s to 0.3 s per gage unit U-WAVE event driven mode: 0.5 s data refresh interval • Timer input function (only in simultaneous measurement) Input interval (time): 0.1 s* 4 to 24 hours at maximum • Measurement date / time display function (available in sequential and simultaneous measurements) The display format is subject to the setting of the Excel sheet. *3 The actual number can be less depending on the system configuration. *4 If a shorter time is set, a priority is given to the longer time compared with the actual communication time.
Optional Accessories for USB-ITPAK
USB Foot Switch Adapter USB-FSW
This USB adapter for connecting a PC is required when using the Foot Switch ( 937179T ) in USB-ITN . A dedicated VCP driver for this adapter is included in USB-ITPAK .
Language support • Operation language (15 languages)
• With USB-ITPAK , application of the foot switch can be set. • Data control: “Data request”,“Data cancel”, “Data skip” • Character string input (e.g. GO/NG, etc.) Note: USB-FSW is used for installation of the VCP driver. Main specification
Japanese, English, German, French, Spanish, Italian, Czech, Swedish, Turkish, Polish, Hungarian, Russian, Korean, Chinese (traditional / simplified)
Foot switch ( 937179T )
• Operation manual (PDF file) Japanese, English, German Order No. Model USB-FSW Order No. 06ADV384
Foot Switch Adapter USB-FSW
USB-FSW
Overall length: 160 mm