Depth Gage
Depth Micrometer SERIES 329, 129 — Interchangeable Rod Type
• Interchangeable rods provide a wide measuring range.
• Data output function (329 Series) allows integration into statistical process control and measurement systems (refer to section A).
Functions of series 329 Origin point setting (ABS measurement system): Resets the ABS origin at the current spindle position to the minimum value of the measuring range and switches to ABS mode. Zero-setting (INC measurement system): A brief press on the ZERO/ABS button sets display to zero at the current spindle position and switches to the incremental (INC) measuring mode. A longer press resets to the ABS measuring mode. Hold : Pressing the HOLD button freezes the current value in the display. This function is useful for preserving a measurement in situations of poor visibility where the instrument must be moved away from the workpiece before the reading can be recorded. Data output : Models equipped with this function have an output port for transferring measurement data to a Statistical Process Control (SPC) system. Auto power ON/OFF : The reading on the LCD disappears after this instrument is idle for about 20 minutes, but the reading and measurement mode are retained. Turning the spindle causes the reading to reappear. Error alarm : In case of an overflow on the LCD or a computing error, an error message appears on the LCD, and the measuring function stops. This prevents an instrument from giving an erroneous reading. Also, when the battery voltage drops to a certain level, the low-battery-voltage alarm annunciator appears well before the micrometer becomes unusable. Function lock : This function allows the PRESET (origin point setting) function and the ZERO (zero-setting) function to be locked to prevent these points being reset accidentally.
329-350-30
D
SPECIFICATIONS Inch/Metric
Parallelism between reference face and measuring rod face (in)
Zero point error of rods (in)
No. of rods
Range (in)
Base (in)
Base Flatness (in)
Rod Flatness (in)
Order No.
Resolution
Accuracy
Digimatic (LCD) 329-350-30 0 - 6
0.00005 in/ 0.001 mm 4×0.63 0.00015 in/ 3 μm
0.00035
±0.0002 6
0.00008 0.000012
0.0001 in/ 0.001 mm
329-351-30 0 - 12
0.0005
±0.0003 12
Metric
Parallelism between reference face and measuring rod face (μm)
Zero point error of rods (μm)
Range (mm)
Resolution (mm)
Base (mm)
Base Flatness (μm)
Rod Flatness (μm)
No. of rods
Order No.
Accuracy
Digimatic (LCD) 329-250-30 0 - 150 0.001 101.6×16 3
7
±4 ±6
6
2
0.3
329-251-30 0 - 300
10
12
Inch
Parallelism between reference face and measuring rod face (in)
Zero point error of rods (in)
No. of rods
Range (in)
Graduation (in)
Base (in)
Base Flatness (in)
Rod Flatness (in)
Order No.
Accuracy
Optional Accessories Order No. Type
Analog
Description
129-129 129-126 129-130 129-127 129-131 129-128 129-132
0 - 2 0 - 3
4×0.63 2.5×0.63 4×0.63 2.5×0.63 4×0.63 2.5×0.63 4×0.63 2.5×0.63 4×0.63 2.4×0.63
0.00008 0.00005 0.00008 0.00005 0.00008 0.00005 0.00008 0.00005 0.00008 0.00005
0.00025
2 3
±0.00015
USB Input Tool Series USB Keyboard Signal Conversion Type IT-020U
0.00030
264-020
—
0 - 4
4
±0.00020
0.001
0.00015
0.000012
0 - 6
0.00035
6
05CZA662 05CZA663 06AFM380B
B Connection cable (1 m) B Connection cable (2 m) B USB Input Tool Direct (2 m)
129-149 0 - 12 129-150 129-331* 0 - 4 129-332* 0 - 6
0.00050 0.00030 0.00035
±0.00030 12
±0.00020 4
6
02AZD730G IP67 U-WAVE-T 02AZD880G Buzzer U-WAVE-T 02AZE200 —
* Half Base models
Metric
Parallelism between reference face and measuring rod face (μm)
Zero point error of rods (μm)
Range (mm)
Graduation (mm)
Base (mm)
Base Flatness (μm)
Rod Flatness (μm)
No. of rods
U-WAVE-T mounting bracket
Order No.
Accuracy
Connection cable for U-WAVE-T (160 mm) Connection cable for U-WAVE-T For foot switch
02AZD790B
B
Analog 129-154 0 - 25 129-155 129-109 0 - 50 129-113 129-110 0 - 75 129-114 129-111 0 - 100 129-115 129-112 0 - 150 129-116 129-152 0 - 300 129-153
1.3
63.5×16 101.6×16 63.5×16 101.6×16 63.5×16 101.6×16 63.5×16 101.6×16 63.5×16 101.6×16 63.5×16 101.6×16
1
2
5
02AZE140B
B
1.3
±3
2
2
1.3
3
264-622 264-623 264-626 264-627
IP67 U-WAVE-TM Buzzer U-WAVE-TM IP67 U-WAVE-TMB Buzzer U-WAVE-TMB
2
6
3
0.3
0.01
1.3
4
2
±4
1.3
7
6
2
1.3
10
±6
12
2 • Power source: SR44 battery (1 pc.), 938882 included as standard (for operational checks) • Battery life*: Approx. 2.4 years under normal use • Standard Accessories: 301336 Spanner, 04GAA274 Spanner, 202863 Hex-Spanner
Connecting unit for U-WAVE-TM
02AZF310
IP67
D-65