MAC CAT-1006 FINAL

Height Gage

Digimatic Height Gage SERIES 192 — Multi-function Type with SPC Data Output

Functions • Origin-setting (ABS measurement mode): Any arbitrary value can be stored as the origin point. • Zero-setting (INC measurement mode): Displayed value can be set to zero at any arbitrary position of the slider. • Origin restoration: Previously set origin is restored when switching back to ABS mode. • Presetting (ABS INC measurement mode): Displayed value can be set to any arbitrary value, including negative values. • Measuring direction Measuring direction can be switched at the press of a button. • Data hold Display value can be held. Reverts to ABS or INC mode when cancelled. • A larm: Error message is displayed when overflow or overspeed of displayed value arises and measurement is stopped. • Data output: Allows integration into statistical process control and measurement systems (refer to Section A). • Fine and coarse height adjustment through knob and wheel combination. Slider height adjustment wheel allows fine and coarse height adjustment. • Probe-tip diameter compensation: An adjustment is applied to the raw measurement data to compensate for the effect of the size of the spherical contact point used by the bidirectional touch-trigger probe. • Presetting (2 positions): With two preset functions, two reference heights can be used relative to a surface plate.

• Long reach scriber type. • Double-column structure ensures stable measurements. • Ergonomic base fits comfortably in the hand. • Cannot be used with bidirectional touch- trigger probe. • Inclined handle improves slider ergonomics. • Coarse and Fine feed. • 2 Preset reference heights. • Bidirectional touch probe (optional) for more repeatable measurements. • With SPC output.

D

192-630-10

SPECIFICATIONS Inch/Metric Order No.

Response speed (mm/s)

Range (in)

Resolution

Height (mm) Mass (kg)

Accuracy* (in)

Standard Accessories Order No. Description

192-630-10 192-631-10 192-632-10 192-633-10

0 - 12 0.01 mm/0.005 mm (selectable) 0.0005 in/0.0002 in (selectable) 0 - 18 0 - 24 0 - 40

±0.001 ±0.002 ±0.002 ±0.003

475 649 802

4.7 7.5 8.3

Models

Approx. 500

192-613-10 192-614-10 192-615-10 192-630-10 192-631-10 192-632-10 192-633-10 192-613-10 192-614-10 192-615-10 192-630-10 192-631-10 192-632-10 192-633-10

1228

15.7

07GZA000

Scriber

Metric

Response speed (mm/s)

Order No. 192-613-10 192-614-10 192-615-10

Range (mm) Resolution (mm)

Height (mm) Mass (kg)

Accuracy* (mm)

900258

Scriber

±0.02 ±0.05 ±0.07

475 802

4.7 8.3

0 - 300 0 - 600 0 - 1000

0.01 / 0.005 (selectable)

Approx. 500

1228

15.7

Scriber clamp box

05GZA033

• Power source: SR44 battery (1 pc.), 938882 included as standard (for operational checks) • Battery life: Approx. 3,500 hours in continuous use *  E MPE (ISO 13325:2012). Largest value across the measuring range.

Scriber clamp box

901385

DIMENSIONS

Optional Accessories Order No. Type



Unit: mm

192-615-10, 192-633-10

192-613-10, 192-614-10, 192-630-10, 192-631-10, 192-632-10 ( ): 192-614-10, 192-632-10

Description

213

40

213

40

USB Input Tool Series USB Keyboard Signal Conversion Type IT-020U

264-020

30 (32)

63 (70)

30 (32)

63 (70)

Connection cable for IT / DP / MIG (1 m) Connection cable for IT / DP / MIG (2 m)

905338

F

905409

F

06AFM380F 02AZD730G

F USB Input Tool Direct (2 m)

IP67 U-WAVE-T 02AZD880G Buzzer U-WAVE-T 02AZE990 —

9*

9*

9*

9*

U-WAVE-T mounting bracket

Connection cable for U-WAVE-T (160 mm) Connection cable for U-WAVE-T For foot switch

02AZD790F

F

91 (120)

135 (180)

150

250

150

250

91 (120)

135 (180)

02AZE140F

F

*0.25 in for Inch models.

D-54

Powered by